Ultrasonic Level Sensor Ultrasonic Digital Tank-O-Meter

How does is work? The sensor produces ultrasonic pulses. The liquid reflects the pulses. Reflected pulses are sampled and processed to determine the current level and simultaneously compensated for temperature fluctuation. A signal is subsequently sent to the digital display where it is converted and displayed in any single or dual engineering unit. (i.e. inches/Gallons; mm/Liters, etc.) Non-linear calibration for virtually any shape thank is optional.


Ultrasonic Diagram
  • Type "U" Ultrasonic Digital Tank-O-Meters® are provided with (2) user programmable setpoint relays. (For alarms, pump/valve on/off, maintaining levels) and an analog output (4-20 mA, 0-10VDC or 0 to 5 VDC). Serial Outputs are also available.

Ultrasonic Digital Tank-O-Meter® Type "U"
Specifications

#Digits/Characters4-1/2
User InterfacePush-button -- Front Panel
CalibrationPassword Access Via Push-Buttons (Display) and BCD Switches On Sensor (Systems Are Supplied Pre-Calibrated for Application) Any Engineering Unit.
Dual Unit CalibrationOptional (i.e. Inches/Gallons, mm/Liters)
Non Linear CalibrationOptional
Ranges0 to 12 Feet; 0 to 25 Feet; 0 to 30 Feet
Operating Temp. (Sensor)-10 to +160F Compensated; CIP to 200F
Operating Temp. (Display)0F to +130F
Sensor Mounting3/4" NPT, 2" NPT, Sanitary CIP 3/4" to 3"
Sensor EnclosureNEMA 4; NEMA 7 Explosion Proof Class I Group BCD, Div. 1
Sensor MaterialCPVC, Kynar, 316SS, Teflon
Sensor Pressure RatingCPVC, Kynar, 50 PSIG; 316SS, 250 PSIG; Teflon, 100 PSIG
Repeatability0.125 Inch
Sensor Resolution0.1 Inch
Sensor Near Zone Min.3/4" NPT 6 Inches; 2" NPT 12 Inches
Lost Echo IndicationLED (In Sensor Housing) Steady "On" = Normal Operation; Blinking = Lost Echo
Lost Echo EffectSystem Uses "Last Known" Valid Value
Beam Angle3/4" - 5 Degrees; 2" - 14 Degrees
System Accuracy0.25% Full Scale
Output (Display)4-20 mA, RS232 or RS485
Power:115 VAC, (220 & DC Optional)
Electrical Connection:Rear Screw Terminal Block
Setpoint Output Relays:Fully Programmable: 2 Dry Contact Relay Rated 5 Amp (Non-Inductive @ 115 VAC.)

Ultrasonic Digital Tank-O-Meter Display Enclosed with Level Alert Alarm System

Bulletin UD398


These pages are Copyright © 1997-2016 Uehling Instrument Company. All rights reserved.